Bryant Air Conditioners for Your Grand Rapids Home
If the thermostat reaches its setting but the house still feels humid, temperature is only part of the problem. When comparing a new air conditioner, consider how it runs, how it manages moisture, and how it works with your indoor equipment.
Schaafsma’s Bryant options include the Legacy 134SAN, Preferred 146SAN, and Preferred 148TAN. The first two provide single-stage cooling; the 148TAN adds a lower cooling stage for days when full output is unnecessary.
Compare Bryant Air Conditioner Models
If columns are cut off, swipe sideways to view the full table.
| Model | Cooling Operation | Model-Family Maximum | Reason to Consider It |
|---|---|---|---|
| 134SAN02400N Legacy™ Line |
Single-stage | Up to 16 SEER2 | Straightforward cooling with one operating stage |
| 146SAN02400W Preferred™ Series |
Single-stage | Up to 16.5 SEER2 | Single-stage cooling with connected diagnostic capability |
| 148TAN02400W Preferred™ Series |
Two-stage | Up to 18 SEER2 | A lower cooling stage for steadier comfort and humidity management |
SEER2 figures are Bryant’s published model-family maximums, not confirmed ratings for these exact outdoor units. Installed efficiency depends on the matched indoor coil, furnace or air handler, and configuration. Ask for the AHRI-rated equipment combination in your proposal. Connected diagnostics require compatible equipment, an internet connection, and permission to share data.
Legacy™ Line Air Conditioner
Bryant Legacy™ Single-Stage Air Conditioner — 134SAN
Straightforward cooling for everyday use
Model: 134SAN02400N
The 134SAN cools at one output level whenever the thermostat calls for air conditioning. It is a practical starting point if you want straightforward operation and do not need a second cooling stage.
Bryant lists the 134SAN family at up to 16 SEER2. Your system’s rating depends on the indoor equipment paired with the outdoor unit. Compare the complete installation proposal, including sizing and airflow needs, rather than choosing by the family’s highest rating alone.
Preferred™ Series Air Conditioners
Bryant Preferred™ Single-Stage Air Conditioner — 146SAN
Single-stage cooling with connected service features
Model: 146SAN02400W
The 146SAN retains single-stage operation while adding features such as a compressor sound blanket and InteliSense™ connected diagnostics. With a compatible InteliSense-enabled Bryant thermostat, internet access, and your permission, equipment data can be shared with your dealer to help with service.
The model family reaches up to 16.5 SEER2. Consider it if you want to compare additional equipment features without moving to two-stage cooling. The exact efficiency rating should be confirmed for the proposed indoor and outdoor equipment combination.
Bryant Preferred™ Two-Stage Air Conditioner — 148TAN
A lower cooling stage for milder days
Model: 148TAN02400W
A mild, humid afternoon may need less cooling than the hottest part of a summer day. The 148TAN has a lower stage for lighter demand and a higher stage when more cooling is needed. Longer operation at lower output can help limit temperature swings and support moisture removal when the system is properly matched and configured.
With model-family ratings up to 18 SEER2, it has the highest published efficiency ceiling of these three options. Compare it if humidity and changes in room temperature are part of what you want to improve.
What to Check Before Replacing Your Air Conditioner
Tell your installer which rooms stay warm, when the house feels humid, and whether the current system cycles on and off frequently. Those details help separate equipment limitations from ductwork, airflow, or insulation problems.
Ask for a cooling-load calculation to guide sizing and a proposal that identifies the outdoor unit, indoor coil, and compatible furnace or air handler. Compare the certified system efficiency, controls, and installation work together. A larger outdoor unit is not automatically a better choice.
Bryant Air Conditioner FAQs
What is the main difference between these three Bryant air conditioners?
The 134SAN02400N and 146SAN02400W use single-stage compressors. The 148TAN02400W uses a two-stage compressor, allowing lower-output cooling when demand is lighter. Their model families also differ in maximum efficiency and available features.
What does SEER2 mean?
SEER2 stands for Seasonal Energy Efficiency Ratio 2. It measures cooling delivered relative to electricity used under standardized seasonal testing. A higher rating indicates greater tested efficiency, but actual electricity use depends on weather, thermostat settings, the home, and installation.
Will my air conditioner achieve the maximum SEER2 shown?
Not necessarily. The figures above describe model-family maximums. The rating for your installation depends on the specific outdoor unit and matched indoor equipment. Ask for the AHRI certificate or reference number for the combination in your proposal.
Can two-stage cooling help a humid house?
It can. A lower cooling stage allows longer cycles when conditions permit, giving the system more time to remove moisture. Correct sizing, indoor airflow, and compatible controls matter. Persistent humidity may also require attention to air leakage, ventilation, or separate dehumidification.
Do I need to replace my furnace when I replace the AC?
Not always. In a central system, the furnace blower may also move air during cooling. Whether it can remain depends on its condition, airflow capability, and compatibility with the new indoor coil, outdoor unit, and controls. Have the complete equipment combination reviewed before deciding.
Will a larger air conditioner cool my home better?
Not necessarily. An oversized system can cool quickly and shut off before removing enough moisture. A cooling-load calculation considers the home’s size, insulation, windows, sun exposure, and other factors to help determine appropriate capacity.
How much can I save with a new air conditioner?
Savings depend on your current system’s efficiency and condition, the replacement system’s certified rating, electricity prices, and how you use it. Compare matched-system ratings and installation costs before estimating savings; a higher SEER2 number does not guarantee a specific reduction in your bill.
Compare Your AC Options with Schaafsma
Bring your questions about warm rooms, summer humidity, and cooling costs to Schaafsma. Ask about the Bryant 134SAN02400N, 146SAN02400W, and 148TAN02400W to compare equipment options for your Grand Rapids home.
Product images represent the model families. Efficiency figures are manufacturer-published family maximums and are not confirmed ratings for the exact models shown. Final performance depends on equipment matching, sizing, installation, and operating conditions.